Hot Product
banner

истакнути

China OEM Medium voltage cable Pricelist – Self-Supporting Aluminum Cable – Holley



Product Detail

Product Tags

Our aim is usually to give superior quality items at aggressive rates, and top-notch company to clients around the earth. We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications forKeyboard meter, Anchor bolt, Сабирница, We have expanded our business into Germany, Turkey, Canada, U. S. A. , Indonesia, India, Nigeria, Brazil and some other regions of the world. We are working hard to be one of the best global suppliers.
China OEM Medium voltage cable Pricelist –Self-Supporting Aluminum Cable– HolleyDetail:

Specifications

DESCRIPTION

УНИТ

ВРЕДНОСТ

ВРЕДНОСТ

ВРЕДНОСТ

ВРЕДНОСТ

ВРЕДНОСТ

1

ГЕНЕРАЛ

 

3×35 + 1×16 + NA25 mm2

3×50 + 1×16 + NA35mm2

3×70 + 1×16 + NA50 mm2 

3×25 + 1×16 + NA25 mm2 

3X120 + 1X16 + NA70 mm2

 

Manufacturing standard

 

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

NTP 370.254

2

DESIGNATION

ЦААИ

ЦААИ

ЦААИ

ЦААИ

ЦААИ

 

Rated Voltage Uo / U

kV

0,6 / 1

0,6 / 1

0,6 / 1

0,6 / 1

0,6 / 1

3

TERMS OF USE

 

Maximum temperature in permanent regime.

° Ц

90

90

90

90

90

 

Maximum temperature in overload regime. 

° Ц

130

130

130

130

130

 

Maximum temperature in short-circuit mode (5 s)

° Ц

 250

 250

 250

 250

 250

4

CABLES GATHERING:

 

Maximum wireways, depending on the diameter of thePhase wire

Тимес

60

60

60

60

60

5

PHASE CABLE:

 

Стандард

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 

Материјал

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated Aluminum

 

Nominal section

мм2

35

50

70

25

120

 

Класа

2

2

2

2

2

 

Minimum number of wires

бр.

7

6

12

6

15

 

Maximum electrical resistance in DC at 20 ° C

Охм / км

0.868

0.641

0.443

1.20

0.253

 

Insulation
Материјал

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.52

1.52

1.14

2.03

Minimum thickness at one point

mm

1.03

1.37

1.37

1.03

1.83

6

STREET LIGHT CABLE

 

Стандард

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

 NTP IEC 60228

NTP 370.250

 

Материјал

 Pure Aluminum without Coating

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 Pure uncoated aluminum

 

Nominal section

мм2

16

16

16

16

16

 

Класа

2

2

2

2

2

 

Minimum number of wires

бр.

7

6

6

6

6

 

Maximum electrical resistance in DC at 20 ° C

Охм / км

1.91

1.91

1.91

1.91

1.91

 

Insulation

 

Материјал

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

 

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

 

Minimum content of carbon black in XLPE

%

2

2

2

2

2

 

Minimum average thickness

mm

1.14

1.14

1.14

1.14

1.14

 

Minimum thickness at one point

mm

1.03

1.03

1.03

1.03

1.03

7

NEUTRAL CABLE SUPPORT
Стандарди

NTP 370.258

 NTP 370.258

 NTP 370.258

 NTP 370.258

NTP 370.258

Cable Material

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Aluminium alloy

Conductivity

% ИАЦС

52.5

52.5

52.5

52.5

52.5

Nominal section

мм2

25

35

50

25

70

Number of wires

7

7

7

7

7

Wire diameter

mm

2.13

2.52

3,023

2.13

3.57

 

Minimum tensile strength

kN

7.72

10.81

15.44

7.72

20.95

 

Nominal Mass

кг/км

68.4

95.7

136.8

68.4

191.5

 

Density at 20 ° C

кг / м3

2703

2703

2703

2703

2703

 

Electrical resistivity at 20 ° C

Ωмм2 / м

0.032840

0.032840

0.032840

0.032840

0.032840

 

Maximum electrical resistance in DC at 20 ° C

Ω / км

1.3511

0.9651

0.6755

1.3511

0.4825

 

Insulation
Материјал

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

Cross-linked polyethylene

КСЛПЕ

XLPE requirement

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

According to table 2 of NTP 370.254

Minimum content of carbon black in XLPE

%

2

2

2

2

2

Minimum average thickness

mm

1.14

1.14

1.52

1.14

1.52

Minimum thickness at one point

mm

1.03

1.03

1.37

1.03

1.37


Product detail pictures:

China OEM Medium voltage cable Pricelist –Self-Supporting Aluminum Cable– Holley detail pictures


Related Product Guide:

We believe in: Innovation is our soul and spirit. Quality is our life. Customer need is our God forChina OEM Medium voltage cable Pricelist –Self-Supporting Aluminum Cable– Holley, The product will supply to all over the world, such as: Burundi, Florence, Honduras, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.

Leave Your Message
vr